Advanced Operation
4. Launch a web browser and login to the web GUI. Refer to Introduction to the Web GUI (page 55) for more
information. The factory-default username and password are listed below:
Username: root
Password: Atlona
5. Click Control in the side menu bar.
6. Select the proper baud rate, data bit, parity, and stop bit settings for the HDBaseT OUT port. These settings
must correspond with the RS-232 settings of the display (sink) device. Referring to the example diagram, on the
previous page, HDBaseT OUT 3 (Zone 4) will need to be congured.
7. Click the Save button to commit changes.
8. Use the following command to send a command to the display (sink) device, where display_command is the
command data to send:
RS232Zone4[display_command$0d]
$0d (carriage return) should only be added to end of the string if the sink device is expecting this character.