Atlona AT-OMNI-111 handleiding

153 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 153
Using OmniStream
with Velocity
Device Manager
23
1. Locate the IP Input 3 window group and verify that the Enable toggle switch is enabled. When enabled, the
toggle switch will be green. Perform the same procedure for the IP Input 4 window group.
2. Under the Input 3 window group, enter 226.0.10.1 in the Multicast Address eld. Under the IP Input 4
window group, enter 226.0.10.2 in this eld. These multicast IP address are the same addresses that were
specied under the Audio > Destination Multicast/Unicast Address eld for the encoders.
3. In the Port eld, enter 1100 under both IP Input 3 and IP Input 4 window groups. These are the same port
settings that were entered under the Audio > Destination UDP Port eld for the encoders.
4. Click the SAVE button, under the IP Input 3 and IP Input 4 window groups to commit changes.
Audio Conguration
Basic Conguration Tutorial
1
2
3
4
Although there is no hard and fast rule for which IP Input window groups should be used for video, audio, and/or
control, it can be helpful to visualize the IP Input window groups as columns and rows to better organize the IP data.
The following tables were used to organize the data.
Input Conguration Notes
IP Input Encoder 1 Information
IP Input 1 Video (226.0.0.1:1000)
IP Input 3 Audio (226.0.10.1:1100)
IP Input Encoder 2 Information
IP Input 2 Video (226.0.0.2:1000)
IP Input 4 Audio (226.0.10.2:1100)
Table 1.3 - Video and Audio information for Encoder #1 and Encoder #2.