EN7
www.afx-light.com
heatupautomaticallywhentheDMXsignalisdisconnected.Automaticheatingfunctioncanbe
set on or off.
IfthemachineisconnectedtoaDMXsignal,theheatingcanonlybestartedbytheDMXcontrol-
ler.
SET CHANNEL MODE
Please refer to the MENU chapter to set to the desired number of channels.
SET DMX ADDRESS
PleasesettheDMXaddressaccordingtotheselectedchannelmode:
Ifthemachineissetto2channels,pleasesettheDMXaddressto1,3,5,7,etc.
Ifthemachineissetto3channels,pleasesettheDMXaddressto1,4,7,10,etc.
RFID TIME CARD
Inordertoavoidmisuse,failuresandaccidentscausedbyunqualiedpersons,themachinecan
only be used with a special RFID time card.
Eachswipeofthecardrechargestheoperationtimefor12minutes.Youcanonlyswipethecard
twice for 24 minutes operation max.. The card can only be swiped again when the remaining time
is less than 20 minutes.
START TO SPARK
Turn on your DMX controller
Turn on the heating function
TheheatingfunctionofthesecondDMXchannelhasthevalue240-255.Ittakesabout5minutes
to preheat after power on.
When the heating is turned on, the HEAT indicator light on the machine will turn to red and the
READYindicatorashesgreen.
When heating is completed, the READY indicator lights steadily green and the machine enters
into sparking status.
ADJUST SPARKING HEIGHT
Adjustthesparkingheightviachannel1.TheDMXvalueofheightadjustmentis11-255.
The maxiumum height of indoor and outdoor granule is different. The maximum height of indoor
granuleis3.5mwhileoutdoorgranuleis5meters.Theheightanddirectionarealsoaffectedby
wind conditions.
ADJUST SPARKING DENSITY
The machine has an independent sparking density adjustment. You can control the density dur-
ing sparking which allows more special effects during the show.
The third channel is dedicated to the density adjustment. The density can be adjusted between
30and100%.Thedefaultsparkingdensityis100%.TheDMXvaluesare0-255.0means100%
density.ThehighertheDMXvalue,thelowerthedensity.
USE OF THE REMOTE CONTROL
A
DIGITAL REMOTE
CONTROLLER
B
C
D
ON
HEIGHT
CLEAR MATERIAL
OFF/CODE
Turnonpoweranddon'tconnectaDMXsignal.
Ontherstscreenhold on the control panel of the machine
for 2 seconds until the display shows "Control Pair Remoter
315M".
Press "B" on the remote control until the display shows "Code
Success".
One remote control can control up to 4 machines.
Please note that the DMX signal must be disconnected during pairing and use of the remote control, otherwise the remote will not work.
Sparkingstopsautomaticallyafter30secondsandclearingmaterialstopsafter5seconds.