SKY-MXM-A500 User Manual 12
2.4 Reset Requirements
System reset may be deasserted only after the assertion of the PWR_GOOD signal.
Figure 2.3 shows the reset requirements relative to the PWR_EN and PWR_GOOD
signals. This sequence must be followed on initial power on, system reset, and
resume from suspend/hibernate.
Figure 2.3 Reset Sequencing
2.5 Mechanical and Environmental Specifications
Table 2.3 describes the mechanical characteristics of the packages.
Note! In order to reduce boot time, a system that monitors the PWR_GOOD
signal is allowed to violate the TPVPERL specification as long as the
TPERST-PG timing is still met.
Table 2.3: DVI-I DDC Mapping
Symbol Parameter Min. Nominal Max. Units Notes
P
cont
Maximum allowable pres-
sure during PCA, system
assembly, and operation
-
≤60
≤80 (die
edge)
psi 1
Tpkg
Maximum allowable package
temperature during device
operation
- ≤ TBD °C 2
e
max
Maximum allowable strain
during PCA, system assem-
bly, or operation
≤ 500 μstrains 3