Note! 1. This specification is based on the following conditions:
a. This specification is based on solder ball deformation and die
chips and cracks. Additional requirements may be needed to meet
the thermal performance and/or long term reliability as to specific
applications.
b. When a compliant thermal interface is used between die and
heat sink, the bond line thickness must have less than 20% in vari-
ation.
c. The pressure should be measured on the top of the die surface
by an instrument equipped with pressure sensors. See details in
“GPU Load Distribution Measurement Application Note”.
d. Nominal pressure is the total force divided by the die surface
area. Since the pressure may have variations across the entire sur-
face, the following additional requirement is applied:
i. The pressure has to be measured from the top of the die sur-
face with a grid resolution of 1x1 mm2 for the pressure sensor.
ii. Both nominal and maximum pressure requirements must be
met.
2. The maximum package temperature allowed includes the device
case and/or junction temperature.
3. Strain measurement shall follow IPC-9704, particularly for the fol-
lowing items:
a. The strain shall be measured on the top side of the PCB close to
the four corners of the package. A rigid PCB is assumed.
b. For generic application, the max. allowable strain must be no
more than 500 μstrains for a board thickness from 1.0 to 3.2 mm. A
separate requirement may be specified and the qualification test
should be performed if:
i. A sensitive PCB laminate and build-up structure is used where
the pad cratering occurs at a PCB strain of 500 μstrains or below.
ii. A weak surface finish is used on the PCB where a cracked sol-
der joint has been observed at a PCB strain of 500 μstrains or
below.
iii. The strain rate is too high (.5000 μstrains/second) during the
PCA operations.
c. For PCB thickness of less than 1.0 mm, the max. allowable
strain shall follow IPC 9704.