11 SKY-MXM-A500 User Manual
Chapter 2 System Requirements
2.2 Input Voltage Requirements
Input voltage to the GPU must strictly follow the ranges listed in the below table (ref-
erence to GND).
Operating outside the required voltage range will cause permanent damage to the
GPU.
2.3 Module Power Down and Power Up
The MXM module may be powered down using the PWR_EN signal. The system
designer may choose to shut down or keep the input power while the module is pow-
ered down. Refer to Figure 2.2 for details.
Figure 2.2 Power Sequencing
Table 2.2: Input Voltage Requirements
Power Rail Min. Typ. Max.
PWR SRC 6.5V 7-20V 22V
5V 4.7V 5V 5.3V
3V3 3.1V 3.3V 3.5V
Note! All output signals from the MXM module are undefined when PWR_-
GOOD is deasserted or undefined. It is recommended that the system
gate critical signals using an appropriate qualifier.