Advantech LEO-S592-TP handleiding

21 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 21
www.advantech.com
17
17
ff
0a
(Software
version)
0101
(V1.1)
ff
0f
(Device Type)
00
(Class A)
5.2 Sensor Data
LEO-S592-TPG0 reports sensor data according to reporting interval (60 min by default).
Channe
l
Type
Description
01
75 (Battery Level)
UINT8, Unit: %
03
67 (Temperature)
INT16, Unit: °C, Resolution: 0.1°C
83
67
Threshold Alarm, 3 Bytes,
Temperature(2B) + 01
93
d7
Mutation Threshold Alarm, 5 Bytes,
Temperature(2B) + Mutation Value(2B) + 02
Example:
1. Periodic Packet
017564 0367f900
Channel
Type
Value
Channel
Type
Value
01
75
(Battery)
64 => 100%
03
67
(Temperature)
f9 00 => 00 f9
=>249*0.1
=24.9°C
2. Temperature Threshold Alarm Packet
83675201 01
Channel
Type
Value
83
67
(Temperature)
52 01 => 01 52 => 338*0.1 = 33.8°C
01 => Temperature Alarm
3. Temperature Mutation Alarm Packet
93d74e01 c602 02
Channel
Type
Value
93
d7
(Temperature Mutation
Threshold)
Temperature: 4e 01 => 01 4e => 334*0.1
= 33.C
Mutation Value: c6 02 => 02 c6 =>
710*0.1=7.1°C
02 => Mutation Alarm
5.3 Downlink Commands
LEO-S592-TPG0 supports downlink commands to configure the device. The application port
is 85 by default.