Advantech Server iManager-Enabler Kit PSU-Status Users Maunal Page 19
YM-2301 Status Sensors
Sensor Name
Value
Status
Min
Max
Description
-1
N/A
-
-
Shows PSU0 instead of PSU2 because it
can’t show which PSU is presence when
one PSU is absent.
PSU2_12_OUT-
VOL
Raw Value
OK
11.4
12.6
PSU2-12V output voltage in normal
range (>MIN and <MAX)
FAIL
PSU2-12V output voltage out of normal
range (<MIN or >MAX)
PSU2_12_OUT-
CUR
Raw Value
REF
-
-
PSU2-12V current, reference value only
PSU2_5_OUT-VOL
Raw Value
OK
4.75
5.25
PSU2-5V output voltage in normal range
(>MIN and <MAX)
FAIL
PSU2-5V output voltage out of normal
range (<MIN or >MAX)
PSU2_5_OUT-CUR
Raw Value
REF
-
-
PSU2-5V current, reference value only
PSU2_FAN1-
SPEED
Raw Value
REF
-
-
PSU2 FAN speed, reference value only
PSU2_TEMP1-
TMP
Raw Value
OK
0
59
PSU2-temp1 in normal range (>MIN and
<MAX)
FAIL
PSU2-temp1 out of normal range (<MIN
or >MAX)
PSU2_TEMP2-
TMP
Raw Value
OK
0
89
PSU2-temp2 in normal range (>MIN and
<MAX)
FAIL
PSU2-temp2 out of normal range (<MIN
or >MAX)
Note
Reference to real PSU about PSU1/2 mapping. All MIN/MAX values are referenced
from YM-2301 spec