Advantech Server iManager-Enabler Kit PSU-Status Users Maunal Page 20
Table 3: Appendix Table YM-2301 Status Sensors
AC-155A Status Sensors
Sensor Name
Value
Status
Min
Max
Description
PSU1
1
RUN
-
-
PSU1 power on and running
0
OFF
-
-
PSU1 out of power
-1
N/A
-
-
PSU1 not presence
PSU2
1
RUN
-
-
PSU2 power on and running
0
OFF
-
-
PSU2 out of power
-1
N/A
-
-
PSU2 not presence
PSU_12_OUT-VOL
Raw
Value
OK
11.4
12.6
PSU overall 12V output voltage in
normal range (>MIN and <MAX)
FAIL
PSU overall 12V output voltage out
of normal range (<MIN or >MAX)
PSU_12_OUT-CUR
Raw
Value
REF
-
-
PSU overall 12V current, reference
value only
PSU_5_OUT-VOL
Raw
Value
OK
4.75
5.25
PSU overall 5V output voltage in
normal range (>MIN and <MAX)
FAIL
PSU overall 5V output voltage out
of normal range (<MIN or >MAX)
PSU_5_OUT-CUR
Raw
Value
REF
-
-
PSU overall 5V output voltage in
normal range (>MIN and <MAX)
PSU_3_3_OUT-VOL
Raw
Value
OK
3.135
3.465
PSU overall 3.3V output voltage in
normal range (>MIN and <MAX)
FAIL
PSU overall 3.3V output voltage out
of normal range (<MIN or >MAX)
PSU_3_3_OUT-CUR
Raw
Value
REF
-
-
PSU overall 3.3V output voltage in
normal range (>MIN and <MAX)
PSU_OUT-POWER
Raw
Value
REF
-
-
PSU overall output power,
reference value only
PSU_TEMP1-TMP
Raw
Value
OK
0
50
PSU temp1 in normal range (>MIN
and <MAX)