Advantech Server iManager-Enabler Kit PSU-Status Users Maunal Page 18
APPENDIX: SENSORS LIST
The following uses PSU modules YM-2301 and AC-155A as an example to explain the two
types of PSU sensor lists.
YM-2301 Status Sensors
Sensor Name
Value
Status
Min
Max
Description
PSU1
1
RUN
-
-
PSU1 power on and running
0
OFF
-
-
PSU1 out of power
-1
N/A
-
-
PSU1 not presence
PSU1_12_OUT-
VOL
Raw Value
OK
11.4
12.6
PSU1-12V output voltage in normal
range (>MIN and <MAX)
FAIL
PSU1-12V output voltage out of normal
range (<MIN or >MAX)
PSU1_12_OUT-
CUR
Raw Value
REF
-
-
PSU1-12V current, reference value only
PSU1_5_OUT-VOL
Raw Value
OK
4.75
5.25
PSU1-5V output voltage in normal range
(>MIN and <MAX)
FAIL
PSU1-5V output voltage out of normal
range (<MIN or >MAX)
PSU1_5_OUT-CUR
Raw Value
REF
-
-
PSU1-5V current, reference value only
PSU1_FAN1-
SPEED
Raw Value
REF
-
-
PSU1 FAN speed, reference value only
PSU1_TEMP1-
TMP
Raw Value
OK
0
59
PSU1-temp1 in normal range (>MIN and
<MAX)
FAIL
PSU1-temp1 out of normal range (<MIN
or >MAX)
PSU1_TEMP2-
TMP
Raw Value
OK
0
89
PSU1-temp2 in normal range (>MIN and
<MAX)
FAIL
PSU1-temp2 out of normal range (<MIN
or >MAX)
PSU2
1
RUN
-
-
PSU2 power on and running
0
OFF
-
-
PSU2 out of power