3.3.3. Module Reset
The AIW-356 DQ-N01 module can reset to its initial status by pulling down the RESET# signal
for more than 30ms (50ms is recommended), and module will restart after RESET# signal is
released. The recommended circuit design is shown in the Figure 3-7:
Figure 3-7 Recommended design for reset circuit
There are two reset control timings as below:
⚫ Reset timing 1
st
in Figure 3-8.
⚫ The Host can only control RESET # when restarting the module, and the module PMU is
powered off during reset. It is recommended to use a USB interface connection.
⚫ Reset timing 2
nd
in Figure 3-9.
⚫ The module PMU is powered off during reset (including complete
power-off and power-on timing.
For t
sd
, refer to section 3.2.1.2). It is recommended to use it during host
restart.
Figure 3-8 Reset timing 1
st