Dimmer Manager software
Instruction Manual - page 25
Issue: 004
Lighting Technologies
• to start the automatic detection: click Grab
Grab for All Selected Dimmer Units: one click will transmit the order to all selected units
Grab for This Unit Only: if you want to view the changes while they happen
• Menu Bar > File > Save to save this information in the current *.dim file
Step 2 : the lighting control desk tells us which individual dimmers are used in the show
There are different ways to use this automatic mode; three methods are:
Method No. 1
On the lighting control desk:
• build a cue which includes all the dimmers used in the show
• then set all these dimmers at a DMX level of e.g. 10% (above the Trigger Level)
Method No. 2
On the lighting control desk:
• go through the cues one by one
Learn Show – automatic mode using DMX (grab)
Learn Show is performed manually or automatically. In automatic mode, Used Dimmers are
identified by monitoring their DMX level. If the DMX level reaches a value above the threshold level,
the dimmer is "Used". This information is memorized.
One of the possible approaches on the lighting control desk is:
• build a cue which includes all the dimmers used in the show
• then set these dimmers at a DMX level of e.g. 10% (above the Trigger Level)
Step 1: start the automatic Learn Show mode
In Dimmer Manager:
• select the dimmer units required in the show
E.g. by selecting some Groups, or by selecting the NETPORT XT
• Menu Bar > Dimmers > Command > Learn Show