AccuTemp Evolution N61201D060 handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 13 van 28
Installation Manual I Installation
11
MP4010-1809
3.8.4 Flame Sense Rectification
The Evolution Gas Steamer utilizes a flame sensing circuit to
determine if the system has proper combustion. When the
system is turned on, gas is sent to the burner and an electronic
ignition tries to ignite the burner. The ignition module then
checks to see if flame is established in the burner.
If the flame sense feedback is within the proper range the
system will stay on until the pressure switch opens. The ignition
module continues to monitor the voltage and as long as its
within the proper range the burner will stay on. If the flame
sense reading falls below the threshold of 2.5uA (microamperes)
the steamer will go into lock out and will stop heating. There is
no exterior signal for a lockout.
1. The flame sense should be monitored and recorded as part
of the install.
2. To test for flame sense, connect a multimeter to the FC+
and FC- pins on the ignition module (FIGURE 8). Set the
multimeter to test for microampere.
3. Run the unit and monitor the reading.
4. If the gas pressure is set correctly for the gas type the
reading should be 4 to 6 µA (Micro Ampere)
5. The air intake shutter is factory set to a value of 2.5 to 5.The
gap has been pre-set at the factory for best combustion
performance (FIGURE 9).
FIGURE 8
FC + & FC 
FIGURE 9
AIR SHUTTER

Bekijk gratis de handleiding van AccuTemp Evolution N61201D060, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAccuTemp
ModelEvolution N61201D060
CategorieNiet gecategoriseerd
TaalNederlands
Grootte9044 MB