3.7 Electrical Requirements and Notices
The electrical voltage requirement is listed on the data
plate that is located on the lower left side panel.
All AccuTemp Evolution Gas Steamers are supplied
with a power cord and plug that must be connected to a
standard a 15A (120V) or 20A (240V) grounded receptacle.
Make sure the voltage is within 10% of the voltage listed
on the steamer data plate.
Connection to any other voltage not identified on the
data plate will cause damage to the components and is not
covered under warranty.
Grounding provides a path for electric current to reduce risk of
shock.
This product is equipped with a power cord having a
grounding plug.
The plug must be plugged into a receptacle that is
properly installed and grounded in accordance with all National,
State and local electrical codes or in the absence of local
electrical codes with the National Electric Code, ANSI/NFPA 70,
or the Canadian Code, CSA C22.2 as applicable.
Under no circumstances shall the plugs grounding prong
be cut or bent to fit a receptacle other than the one specified.
Do not use any adapters.
Any in-field modification made that bypass the safety
features of this appliance will result in serious injury or death.
DO NOT DIRECT WIRE THIS APPLIANCE.
Any in-field modifications made without written
authorization from AccuTemp Products, Inc. will void all written
and oral warranties.
3.8 Gas Connections
3.8.1 Gas Requirements and Notices
The Evolution Gas Steamer is manufactured for the use of
gas indicated on the data plate. Contact AccuTemp Products
Technical Service Department if your gas supply does not
match the gas indicated on the steamer data plate.
MINIMUM recommended static pressure for gas is: NG
7inWC, LP 10inWC.
All gas connectors must be in accordance with the local
codes and must comply with the latest edition of the National
Fuel Federal Gas Codes, ANSI Z223.1.
A separate gas shuto valve (not supplied) should be
installed in the gas supply line.
Use a 3/4” or larger diameter dedicated commercial grade gas
supply line capable to handle a minimum of 60,000 BTU to
connect this steamer to the facility supply manifold to ensure a
sucient volume of gas.
The facility supply regulator and manifold must be sized
according to the gas load of all appliances connected to it. If
other gas appliances are connected to the supply manifold,
their gas load must be added to the calculations for properly
sizing the supply manifold and regulator.
Flexible residential appliance connection hoses are not
suitable for this appliance and will void any warranty.
If your steamer is located at an altitude of 2000 feet or
higher, the orifice must be changed to allow appropriate gas
supply to the burners. Please contact the AccuTemp Products
Technical Services Department for assistance.
The steamer is supplied with an internal gas regulator that
is for the gas type and pressures on the steamer data plate. An
external regulator is not required unless the gas suply pressure
is more than 0.5psig. If an external regulator is required it must
be rated 125% of the steamer BTUH rate at the pressure higher
than the rated regulated pressure.
3.8.2 Gas Pressure Verification
The gas supply pressures for the internal regulator must
be verified with a calibrated manometer while the appliance is
operating in maximum load condition.
A 1/8” NPT tap is provided in the front of the internal regulator
to measure the burner STATIC pressure, see FIGURE 7.
Use a pipe joint compound or sealant designed for the use with
liquefied petroleum gas when replacing the 1/8” NPT tap.
Do not use an excessive amount of sealant in order to
prevent potential obstruction of the gas control valve.
3.8.3 Gas Pressure Adjustment Instructions
1. Ensure unit is connected to gas supply.
2. Turn gas o at supply.
3. Remove 1/8” NPT plug from dual solenoid control valve.
4. Use a 1/8” NPT tap to connect a manometer to the control
valve. Ensure manometer is set to read inches water
column.
5. Turn supply on and power unit on.
6. When unit powers on, the pilot valve will open and the
STATIC pressure will be present.
7. Once unit attempts ignition, the main valve will open and
the DYNAMIC pressure will register on the manometer.
8. The DYNAMIC pressure must be set to 5 inch WC.
9. To adjust the pressure, remove the dust cap on the
regulator as seen in Figure 7.
10. Adjustment screw can be turned using a slot head
screwdriver. Adjust while burner is on.
FIGURE 7
1/8” NPT
TAP
DUST CAP ON
REGULATOR