Zodiac Z300 M7 handleiding

22 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 6 van 22
H0439100.A1.EN2013/10
5
Disposingofcondensation:
Warning:yourdevicecanproduceseverallitresofwaterperday.Itisstronglyrecommendedtoguidethe
flowtodrains.
connect a Ø18 interior pipe (not supplied), to the grooved endpiece mounted on the base of the
appliance,
outlet:tothebackorontheside:
2.5Electricalconnections
2.5.1Voltageandprotection
the electri cal supply to the heat pump must include a protection and circuitbreaker device (not supplied)
complyingwiththestandardsandregulationsinforceinthecountry,
additionalprotectionmayberequiredduringinstallationtoprotectagainstovervoltagecategoryII,
thedeviceisdesignedforconnectiontoageneralpowergridwithTTandTN.Sgroundingsystems,
electri
calprotection:circuitbreaker(curveD)orfuse(Am)(see§2.5.3forratings),andwitha30mAdedicated
differentialtripswitch(circuitbreakerorswitch).
electricalconduitsmustbe secured,
toleranceforvoltagevariation:±6%(duringoperation),
use cable suitable for outdoor use, type RO2V or equivalent in countries outside of the European
community,withanouterdiameterbetween9and18mm,
usethecableglandtorunthesupplycableintothedevice.
2.5.2Connections
theelectricalsupplycablemustnotbeexposedtoelementsthataresharp,hotoratriskofbeingcrushed,
checkthatallcablesaresecureandallterminalconnectionsarecorrect.
Looseterminalsmaycausethesupplyterminalboardtooverheatandwillvoidthewarranty.
Thedevicemustbeconnectedtotheearth(grounded)
Riskofelectric shockinsidethedevice
Thedevicemustonlybecommissionedbyaqualifiedandexperiencedtechnician
Ifthepowercableisdamaged,itmustbereplacedbyaqualifiedtechnician
Singlephase Threephase

2.5.3Cablecrosssections
•supply cable crosssection: cables with a maximum length of 20 metres (calculation base: 5A/mm²), must be
checkedandadapteddependingoninstallationconditions.

Z300 Voltage
MaximumIinput Cablecrosssection Electricalprotection
A mm² A
M4 230V50Hz 10 3x2.5 3G2.5 16
M6MD6 230V50Hz 14.5 3x2.5 3G2.5 16
T6TD6 400V50Hz 5 5x2.5 5G2.5 10
M7 230V50Hz 16.1 3x4 3G4 20
MD8 230V50Hz 22 3x6 3G6 25
TD8 400V50Hz 9.4 5x2.5 5G2.5 10
phase(L)+neutral(N)+Earth(PE)