Zodiac Z300 M7 handleiding
Handleiding
Je bekijkt pagina 10 van 22

H0439100.A1.EN–2013/10
9
3.4Winterstorage
Winterstorageisessentialduetotheriskofthecondenserfreezingandbreaking.Thissituationisnot
coveredbythewarran ty.
Toavoiddamagingthedevicewithcondensation,donotcoveritwithanair‐tightcover.
switchthedigitalcontrolpanelto"stand‐by"modebypressingfor3seconds,andcutthepowersupply,
openvalve1,
closevalves2and3,andopenvalves4and5(iffitted),
ensurethatnowaterisflowingthroughtheheatpump,
drainthewater con
denserbyunscrewing the twopoolwaterinletandoutletconnections at the back of the
heatpump,
inthecaseoffullwinterstorageconditionsforthepool:re‐connecttheinletandoutletconnectionstoavoid
foreignbodiesenteringintothecondenser,
inthecaseofwinterstorageforthehe
atpumpalone:donotreconnect theinletandoutletconnectors,instead
placetwoplugs(supplied)onthecondenserwaterinletandoutlet.
covertheheatpumpwithamicro‐breathingoverwinteringcover(optionalaccessory,see§4.3).
4.Maintenance
4.1Maintenanceinstructions
It is recommended that the device be general serviced on a yearly basis to ensure proper operation,
maintainperformancelevelsandpreventsomepotentialfailures.
Thisistheresponsibilityoftheuserandmustbeperformedbyaqualifiedtechnician.
Donotuseahigh‐pressure waterhose.
ensurenoforeignbodiesobstructthefangrid.
cleantheevaporatorwithasoftbrushandafreshwaterjet(disconnectthepowercable),donottwistorbend
themetalblades,thentocleanthedischargepipeofthecondensatesinordertoevacuatetheimpuritieswhich
couldblockit,
clean the outside of the unit wi
th a solvent‐
free product. A specific PAC NET cleaning kit is available as an
optionalextra(see§4.3),
checkthatthewatercondensationflow soutproperlyduringtheoperationofthedevice.
checktheproper operationoftheregulator,
check
electricalcomponents,
checkthatallmetalelementsaregrounded,
checkthetighteningandconnectionsofelectriccablesandthecl eanlinessoftheelectricalcompartment.
4.2Additionalrecommendations
inrelationtothePressureEquipmentDirective(PED‐97/23/CE)
4.2.1Installationandmaintenance
theunitmaynotbeinstall edclosetocombustiblema terials,ortheairductinletofanadjacentbuilding.
withsomedevices,itisessentialtofitprotectiongridsiftheunitisinstalledinanareawithuncontrolledaccess.
during installation, troubleshooting and maintenance, pipes may not be used as steps: the pipe could break
underthewe
ight,spillingrefrigerantandpossiblycausingseriousburns.
whenservicingtheappliance,thecompositionandstateofheatcarryingfluidmustbechecked,aswell asthe
absenceofanyrefrigerant.
duringtheannualunitsealingtestinaccordancewithapplica ble legislation,thehighandlowpressureswitches
must be checked to ensure that they are securely fastened to the coolant ci rcuit and that they cu toff the
electricalcircuitwhentripped.
duringmaintenancework,ensureth erearenotracesofcorrosionoroilaroundcoolingcomponents.
before beginning work on the cooling circuit, stop the devi
ce and wait for a few minutes before fitting the
temperatureandpressuresensors.Someelementssuchasthecompressorandpipingmayreachtemperatures
inexcessof100°Candhighpressureswiththeconsequentriskofseverescalding.