8.4 Control Box Error Codes (VX50 4WD and VX55 4WD)
Thecontrolboxwilldisplayoneoftendifferenterrorcodestoindicatespecicproblemswitheitherthecontrolboxor
mechanically with the cleaner.
To remove an error code after troubleshooting, press any key and the control box turns off.
If an error code is displayed and no key pressed, the screen goes into standby mode after 10 minutes of inactivity.
Press any key to turn the screen back on.
When an error is detected, programming for the control box is temporarily suspended. The button is
turned off.
Press and hold the button to clear the error code and reactivate current programming.
Error Code Cause Solution
1
2
3
(1)Pumpshort-circuit.
(2)Rightsidetractionmotor
short-circuit
(3)Leftsidetractionmotor
short-circuit
Checkforanysmalldebrisoroatingcable
stoppingbrushesfromturningfreely.
Checktheconnectorpinsintheoatingcable
forcorrosionorabentpin.
Turneachwheelonequarterturninone
directionrepeatedlyuntilrotationissmoothand
notcatching,thenrepeatturningwheelinthe
oppositedirectionuntilrotationissmooth.
Ifproblemisnotresolvedthrough
troubleshooting,contactZodiacAfterSales
Supportat1300763021.
4
Pumpmotoroverconsumption Checkforsmalldebrisorhairinthefan.
Cleantheltercanister.
5
6
(5)Rightsidedrivemotors
overconsumption
(6)Leftsidedrivemotors
overconsumption
Checkforanysmalldebrisorhairandthatthe
oatingcableisnotcaught,stoppingbrushes
fromturningfreely.
Turneachwheelonequarterturninone
directionrepeatedlyuntilrotationissmoothand
notcatching,thenrepeatturningwheelinthe
oppositedirectionuntilrotationissmooth.
7
8
(7)Cleaneroatsonthesurface.
(8)Cleaneristurnedonandrunning
outofwater.
Turncleanerpoweroff,thensubmergecleaner
accordingtocorrectprocedure.
9
NOTACLEANERERROR Endofcyclestatuscode.Cleanerfunctionis
normal.Noactionrequired.
10
Cleanerandcontrolbox
communicationerror.
Turncleanerpoweroffthenbackontorestart
theprogram.
Checkconnectionoftheoatingcableonthe
controlbox.
Checktheconnectorpinsintheoatingcable
forcorrosionorabentpin.
Ifproblemisnotresolvedthrough
troubleshooting,contactZodiacAfterSales
Supportat1300763021.