8
❸ Use
3.1 I Presentaon of the regulaon system
Keys
Press and release Press and hold
To conrm a value "On/o"
To browse and adjust values To quickly scroll through the values
Indicator lights
Descripon Steady Flashing O
on
"On/O"
indicator light
Appliance
switched
on
/ Inacve
reg
Heang indicator
lights
Appliance
currently
heang
On hold
Pool at
the desired
temperature
Water ow rate too low (less than 5 m³/h)
Filtraon stopped
Set point temperature greater than pool water
temperature (the indicator ashes for 15
seconds then is lit steadily).
3.2 I Starng the appliance
• Open all valves (V1, V2 and V3) (see §"2.2 I Hydraulic connecons"),
• Start the lter pump,
• Gradually close the by-pass valve (V1),
• Check that the water ow rate is between 5 and 30 m³/h. If the ow rate exceeds 30 m³/h, adjust valve 1
(V1) to reach 30 m³/h maximum,
• Check that there is no air in the circuit,
• Connect the regulaon system to the power supply and turn it on,
• Adjust the set point temperature: to display and change the set point value, press or .
• The temperature is regulated by degrees.
• The set point can be adjusted to between 2°C and 40°C.
• To check that the ltraon me is long enough:
- During the temperature rise phase, water circulaon must be connuous (24 hours/day),
- To maintain the temperature throughout the season, run "automac" circulaon for at least
12 hours/day (the longer this me, the more the operang range of the appliance will suce
for heang).
3.3 I Checks to be carried out aer operang for a few moments
The heater must stop operang when:
• The temperature set point is lowered,
• The regulaon system stops,
• Filtraon stops.