5
3.3Winterstorage
Winterstorageisessentialduetotheriskofbodyoftheheaterfreezingandbreaking.Thissituationis
notcoveredbythewarranty.
switchofftheappliance
switchoffthepowersupply(bydisengagingofthe30mAdifferentialcircuitbreakeroftheheater),
drainthepoolcircuitbyremovingbothconnectionunionfittings.
4.Maintenance
4.1Maintenanceinstructions
It is recommended that the device be general serviced on a yearly basis to ensure proper operation,
maintainperformancelevelsandpreventsomepotentialfailures.
Thisistheresponsibilityoftheuserandmustbeperformedbyaqualifiedtechnician.
visualcheckoftheconditi onofthevariouselectricalcomponents,
retightencablesandsupplyterminalboardshuntsandtheswitch.
4.2Recycling
Thissymbolmeansthatyourdevicemustnotbethrowninthebin.Thedevicemustbecollectedbya
selective system in view of re‐use, recycling or similar. Any substances it may contain which are
potentiallydangeroustotheenvironmentshallbeeliminatedorneutralised.
Requestinformationonrecyclingproce
duresfromyourretailer.
5.Resolutionofproblem
5.1Malfunctionsofthedevice
Dysfunction Causes solution
Orangelightdoesn’t
switchonanymore
circuitbreakerisoff switchoncircuitbreaker
“on/off”switchisoff switchon
thermostatisnotondemand increasesettingofrequiredtemperature
poolwaterdoesn’tcrosstheheater runthefiltrationpump
filterisclogged(waterflow rate
insufficient)
backwashthefilter
filtrationpumpisdrained primethepump
highlimitthermostatisreleased
(cause:warmeroverheating)
resethighlimitthermostat
Caution:ineventofsuccessivereleasesofhigh
limitthermostat,makesureflowrateissufficient
andregular
Theheatermakes
tripelectrical
installation
Theprotectioncircuitbreakeris
underdimensionedonthelevelof
itsgauge(inamp)
putadifferentialcircuitbreakergoodgauged
withrespecttotheintensityconsumedby the
appliance(seetable§2.4.3)
thesectioninmm²ofthesupply
cableisinsufficient
putagoodcablesectionadaptedtotheintensity
consumedbytheappliance(seetable§2.4.3)
thepowerterminalstripcable
and/ortheclampsarebadly
tightenedorbadlyconnected
checktheelectriccon nections
anearthingofelectricalresistance replaceelectricalresistance(realizedbyan
approvedperson)
Orangelightis
flashing:
immediatelyswitch
offtheheaterusing
the“on/off”switch
flowrateisirregular checkinstallationandpump
filterclosetobeclogged backwashthefilter
pumpisdrained primethepump