❶ Installaon
1.1 I Selecng the locaon
• The appliance must be installed at least 2 metres from the pool's edges.
• Do not li the appliance by the body; use its base.
• Installaon is only permied outdoors: provide for a clear space around the appliance as shown in the diagram under
§ "1.2 I Hydraulic connecons".
• Place the appliance on its an-vibraon pads (supplied with the appliance, height adjustable) on a stable, solid and
level surface,
• This surface must be able to bear the weight (see § "5.2 I Technical specicaons") of the appliance (in parcular in
the case of installaon on a roof, a balcony or any other support).
: Front
: Rear
: An-vibraon pads
View of the appliance base from below for installing the an-vibraon pads
The appliance must not be installed:
• With the blowing towards a permanent or temporary obstacle (awning, brushwood, etc.) less than 4 metres away,
• Within range of water or mud jets, sprays or run-o (take the eect of the wind into account),
• Near a heat source or ammable gas,
• Near high-frequency equipment,
• In a locaon where it would be subject to snow build-up,
• In a locaon where it might be ooded by the condensates produced by the appliance when operang.
Tip: to reduce noise produced by your heat pump
• Do not install it under or facing a window.
• Do not lt it towards your neighbours.
• Install it in an open space (sound waves are reected on surfaces).
• Install an acousc screen around the heat pump, respecng the distances (see drawing § "1.2 I
Hydraulic connecons").
• Install 50 cm of exible PVC pipe at the heat pump water inlet and outlet to absorb vibraons.