2.3 I Operaon
Check that there are no tools or other foreign objects in the machine,
Ret the panel providing access to the technical part (see § "5.3 I Dimensions and marking"),
Set the valves as follows: valve B wide open, valves A, C, D and E closed.
: Water inlet valve
: By-pass valve
: Water outlet valve
: Water inlet adjustment valve (oponal)
: Water outlet adjustment valve (oponal)
An incorrect by-pass seng may cause the heat pump to malfuncon.
Check that the hydraulic connecons are correctly ghtened and that there are no leaks.
Check that the appliance is stable.
Turn on the water ow (by acvang ltraon).
Close valve B gradually so that the lter pressure is increased by 150g (0.150 bars).
Open valves A, C and D fully then valve E by half (the air which has built up in the heat pump condenser and the
ltraon circuit will bleed out). If valves D and E are not present, open valve A wide and close valve C by half.
Connect the power supply to the heat pump.
The heat pump is on standby.
Press and hold for 5 seconds to turn on the heat pump.
Set the desired temperature (called the "temperature setpoint" ) (see § "2.4.2 Changing operang mode").
Aer the start-up steps for your heat pump:
Shut down the water circulaon temporarily (by stopping the ltraon or closing valve B or C) to check that your
appliance stops aer a few seconds (via the acvaon of the ow switch).
Reduce the temperature setpoint to below the water temperature to check that the heat pump stops operang.
Switch o the heat pump by pressing and holding for 5 seconds and check that it stops.