Page 21
Page 20
MagnaPool™ | Installation Manual
240VAC Outlet
Relay Switch Box
Light Transformer
Pool Light
Chlorinator
Power pack
LOW VOLTAGE HIGH VOLTAGE
2X OR 4X
LIGHT
TRANSFORMER
Low voltage cable
from transformer
to pool light
Light transformer
plugs into socket
outlet on relay
switch box
Relay switch box
plugs directly into
240VAC for power
Low voltage 2 core cable
wires directly to red
terminal on relay switch
and into AUX 2 terminal
on power pack
Figure 24. Light Transformer, Switch Box and
Chlorinator Connections
8.2.1 Assign Lights
1. Press .
2. Use to select “Aux/Light” then press .
3. Use to select “Assign Lights” then press .
4. Use to select “Aux 2” then press .
5. Use to select “Yes” then press .
6. Use to select “White Light” or “Color
Light” then press .
7. Press to exit.
<-AUX/LIGHTS
-PROGRAMMING
-LOW MODE
-SLAVE MODE
-REVERSING
-HELP MENU
-LANGUAGE
MAIN MENU
<
AUX/LIGHTS
-ASSIGN LIGHTS
-AUX 2
-AUX 1
<
ASSIGN LIGHTS
-AUX 2
-AUX 1
<
AUX SETUP
AUX 2 = LIGHT?
YES
NO
<
AUX 2 = LIGHT
-WHITE LIGHT
-COLOR LIGHT
8.2.2 White Light Operation
1. Press .
2. Use to select “Aux/Light” then press .
3. Use to select “Aux 2/Light” then press .
4. Use to select “On”, “Off”,
or “Set Timers”, then press .
5. Press to exit.
<
AUX 2
-OFF
-ON
-SET TIMERS
8.2.3 Color Light Operation
1. Press .
2. Use to select “Aux/Light” then press .
3. Use to select “Aux 2/Light” then press .
4. Use to select desired color, “Off”,
“On” or “Dene Color”, then press .
5. If “Dene Color” selected, use to select
desired color then press .
6. Press to exit.