MagnaPool™ | Installation Manual
<-PH SETUP
-ORP SETUP
-LOW MODE
MAIN MENU
<-PH SETPOINT
-PH CALIBRATION
-ACID PUMP
-TEST DOSAGE
PH SETUP
<7.2
RECOMMENDED
7.0-7.4
PH SETPOINT
Default pH setting is 7.2.
Use to change the setpoint
by increments of 0.1.
pH setpoint range is from 6.8 (min) to 7.6 (max).
9.3.2 Establish the ORP Setpoint
Establishing the ORP setpoint determines when
chlorine should be produced by the system to
chlorinate the water. Free chlorine level should be
chec d every few days after initial installation.
1. Press .
2. Use to select “ORP Setup” then press
.
3. Use to select “ORP Setpoint” then press
.
4. Use to select value then press .
5. Press to exit.
<
-PH SETUP
-ORP SETUP
-LOW MODE
MAIN MENU
<-ORP SETPOINT
-ORP CALIBRATION
ORP SETUP
CHECK CYANURIC ACID
>30 PPM
TO AVOID ORP ISSUES
<700 MV
RECOMMENDED
650-750 MV
ORP SETPOINT
Default ORP setting is 700 mV.
Acceptable range = 600 mV (min.) - 900 mV (max)
9.4 Prime and Test
the pH Dosing Pump
The dosing pump is deactivated during the first
8 hours of the device in order to prevent acid
exposure during installation. The pH dosing pump
can be directly activated directly in order to perform
a five-minute operating test.
WARNING
Hydrochloric acid is a hazardous chemical that
may cause burns, lesions, and irritations. Handle
with extreme care using protective equipment
(gloves, goggles, coveralls). Refer to the
substance SDS sheet for more information.
Always pour acid into water; do NOT pour water
into acid..
Dispose of the solution according to the appliable
code(s) or standard(s) in effect in the country of
use.
1. Press .
2. Use to select “pH Setup” then press .
3. Use to select “Test Dosage”
then press .
The acid pump will perform a ve-minute
operating test.
4. Press while “Start Test”
is selected to begin.
5. Press while “Stop Test”
is selected to cancel.
6. Press to exit.
<-PH SETUP
-ORP SETUP
-LOW MODE
MAIN MENU
<-TEST DOSAGE
PH SETUP
<
CONNECTIONS
START TEST
CHECK ACID
<
PROCEEDING
STOP TEST
ACID TEST
Pump stops automatically upon completion of the
ve-minute test.
9.4.1 Pause Acid for Pool Service
During regular maintenance, it may be required
to add ‘Alkalinity Up’ (often called buffer). This
will cause a pH sensor to fluctuate its readings.
It is advised to pause acid delivery for 8 hours
whenever ‘Alkalinity Up’ is added to the pool to
prevent the dosing of acid at the same time.
1. Press .
2. Use to select “Acid Pump” then press .
3. Use to select “Stop” then press .
4. Use to select “Yes” Stop Injection for 8
Hours, then press .
5. Press to exit.
<-PH SETUP
-ORP SETUP
-LOW MODE
MAIN MENU
<-PH SETPOINT
-PH CALIBRATION
-ACID PUMP
-TEST DOSAGE
PH SETUP
Acid delivery begins automatically at the end of
8-hour period.
9.5 Programming/Timers
The controller has two internal operating timers.
The timers are used to define the length of time for
the filter pump to operate, and the length of time
for the Salt Water Chlorinator (SWC) to produce
chlorine. This offers the user the advantage of
running their variable speed pump longer at lower
flow rates, without having the chlorinator producing
the whole time.
In order to complete the timer program, it is
necessary to enter and validate both ON and
OFF times. If no timer is set, the filtration and / or
chlorination will run continuously