5.2 I Error code display
Regulator display Possible causes Soluons
Flashing
The regulaon sensor is out of
service or disconnected
Reconnect or change the sensor
Circulang pump
display
(rst LED red)
Possible causes Soluons
• The circulang pump has
detected an electrical
problem
• The circulang pump is
defecve
• Check the power supply voltage
• Replace the circulang pump
The circulang pump is
supplied with electricity
Check the power supply voltage
The circulang pump is blocked
Use a screwdriver to manually release the blockage
through the central hole provided in the circulang pump.
5.3 I Replacing the switch box fuse (depending on the model)
• Turn the appliance o.
• Remove the cover.
• Disconnect the regulator.
• Remove the regulator cover ( ).
• Remove the protecon fuse (T3,15AH250V) ( ).
EN