5.3.3 Calibra ng the ORP sensor
Current sensor measurements
Setpoints
The ORP sensor can be calibrated to 1-point (ORP 470 mV);
The current setpoint is displayed on the home screen when the appliance is switched on.
Turn on the power supply to the appliance.
Switch o the pool's pump and close the necessary valves in order to isolate the cell and the sensors.
• Press
and browse the menu using the bu ons. Press to con rm.
Unscrew and remove the ORP sensor from the POD.
Rinse the  p of the sensor with tap water.
Shake it to remove any residual water. Do not touch the end of the ORP sensor.
Place the ORP sensor in the ORP 470 mV solu on for 1 minutes, and follow the on-screen instruc ons:
Once calibra on is complete, replace the sensor on the POD.
• Press
to exit.
If calibra on is unsuccessful, see “8.1 I Appliance behaviour.