3.2 I Installing the POD kit
The POD Kit is a measuring chamber using patented Quick Fix® technology for installa on on a rigid 50 mm PVC pipe
(with supplied adapter) or 63 mm PVC pipe (without adapter). It contains the following components:
: Flow switch
: pH sensor
: ORP sensor
: pH minus injec on
: Sensor holder
3.2.1 Recommended posi oning
• The cell bypass valves must always be open.
• The sensor-holding POD kit must always be posi oned on a horizontal pipe so that the sensors
are ver cal.
• The POD kit must be the rst unit ed a er the pool lter.
• If the pool is ed with an electric heater, the POD kit must be installed upstream of the
heater (to take readings on unheated water).
• We recommend posi oning the POD kit more than 20 cm from an elbow in the pipe.
• The sensor cables must not be posi oned near high voltage mains electricity cables.
Recommended
pool grounding
Recommended
pool grounding
In-line installa on Installa on on a by-pass
• If an electric heater is installed (instead
of a heat pump), place the POD kit
before this heater (in order to measure
unheated water). In this case, the fl ow
switch must be placed on the bypass on
the xture collar.
Recommended
pool grounding
Installa on with a hea ng system