Zodiac GenSalt OT handleiding
Handleiding
Je bekijkt pagina 12 van 60

10
2.2 I Installing the temperature sensor (depending on the model)
• The water temperature sensor displays the water temperature value on the appliance screen and manages
chlorina on according to the temperature. The sensor must measure the temperature of the water
upstream of any possible hea ng system.
• The sensor is designed to be mounted on rigid Ø50 mm, Ø63 mm or Ø1 ½’’ PVC pipes. Do not install on any
other type of pipe.
• Install the sensor either between the lter pump and the lter, or between the lter and any other
downstream equipment, see “2.1 I Installing the cell”:
- Drill a hole in the pipe using a Ø9 mm (max. Ø10 mm) drill bit, then deburr the hole,
- Install the O-ring provided on the sensor body,
- Secure the sensor using the stainless-steel clamping collar provided. Do not use excess strength.
: Sensor
: O-ring
: Stainless steel clamping
collar
2.3 I Installing the fl ow switch (chlorinator only without pH Link or Dual Link modules)
In cases where a pH Link or Dual Link module is used, the ow switch will be installed on the POD
Kit, see “3.3 I Installing the fl ow switch on the POD kit”
• The ow switch and its 50 mm diameter xture collar supplied as standard (63 mm diameter available
as a spare part) must be installed immediately before the cell and a er any valves present (
). Use the
threaded adapter and the Te on tape provided to install the ow switch on its xture collar.
• Screw the ow switch using using the clamping nut only (screw by hand!) (
).
Clamping
nut
Direc on of water
o w
Installa on on a by-pass In-line installa on
• Failure to comply with these instruc ons could lead to the destruc on of the cell! The
manufacturer cannot be held liable in this case.
• The fl ow switch has a direc on for installa on (arrow indicated on it showing the fl ow
direc on for the water). Make sure that it is correctly placed on its xture collar so that it
stops the appliance's produc on when ltering is stopped.
Bekijk gratis de handleiding van Zodiac GenSalt OT, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Zodiac |
Model | GenSalt OT |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 20621 MB |