39
6.4 I Winterising
The appliance is ed with a protecon system liming chlorine producon in poor
operang condions such as cold water (winter) or low salt.
Acve winterising = ltering operaonal in winter: below 10°C it is preferable to switch o the appliance. Above
this temperature you can leave it running.
Passive winterising = lower water level and drained piping: switch o the appliance and leave the cell dry in place
with any isolaon valves open.
Winterising the sensors = Keep the plasc sensor tube (which contains a storage soluon) for re-use when win-
terising. The sensors must always be stored wet (never dry). They must be stored in the tube lled with a storage
soluon of 3 mol/L KCl or at least in tap water.
6.5 I Preparing the pool for new season
Required acons:
Adjust the water level (too much or too lile).
Check the water parameters: TA/TH/pH/Salinity/Chlorine/Stabiliser/Copper/Metals, and adjust the parameters to
obtain a balanced, healthy pool, see § “3.1 I Balance the water.
Check the condion of the equipment (pump, lter, chlorinator, electrolyc cell).
Inspect the sensors, then clean and recalibrate.
As soon as the salt level reaches the required level (4,000 ppm or 5,000 ppm) and has completely dissolved in the
water, restart the salt water chlorinator.