4.3.13. Seng the “Temperature” alarm triggering
When the measured temperature is outside the congured range, an alarm is displayed. The recorded default
range is 5°C - 40°C. To adjust it:
• From the Conguraon/ mode, press : the minimum value (indicated by “LO”) ashes.
• Press or to adjust this value (select 0 to deacvate the alarm).
• Press to conrm: the maximum value (indicated by “HI”) ashes.
• Press or to adjust this value.
• Press to conrm.
4.3.14. Seng the “Salinity” alarm triggering
When the water’s measured salt concentraon is outside the congured range, an alarm is displayed. The
recorded default range is 2.5 g/L - 8 g/L). To adjust it:
• From the Conguraon/ mode, press : the minimum value (indicated by “LO”) ashes.
• Press or to adjust this value (select 0.5 to deacvate the alarm).
• Press to conrm: the maximum value (indicated by “HI”) ashes.
• Press or to adjust this value.
• Press to conrm.