4.3.10. “Pump stop”: pH pump stop over feed alarm (pH - PH/ORP models)
The pH pump stops rotang if the pH setpoint has not been reached aer a given me, resulng in the display of an
alarm. By default, this programmed safety me is 60 minutes. To adjust it (minimum value: 1 min - maximum value:
120 min):
• From the Conguraon/Pump stop mode, press : “OFF” ashes
• Press to switch to “ON”. The injecon me ashes.
• Press or to adjust this value.
• Press to conrm.
4.3.11. "Auto Cl mV": Automac ORP regulaon (pH/ORP models)
This mode is activated by default on pH/ORP models only. Production stops when the setpoint is passed. To deacvate
the automac mode:
• From the Conguraon/Auto Cl mV mode, press : "ON" ashes.
• Press to acvate it ("OFF").
• Press to conrm.
4.3.12. "Cl EXT": Slave mode
• Ensure that these appliances are properly connected to the power supply in accordance with
the regulaons in force and are protected by a circuit breaker (ltraon unit).
Slave mode transfers control over the chlorinaon funcon to an external controller (ORP or ppm control). Once the
external controller is correctly connected to the connecon point (see § “2.6.2. Detail of connecons”), acvate the
Slave mode:
• From the Conguraon/Cl EXT auto mode, press : "OFF" ashes.
• Press to acvate it ("ON").
• Press to conrm.
•