2.5.6 Connec ng to an auxiliary device = AUX 1 - Dry contact provided for disconnec on from the 230V
power supply (depending on the model)
The chlorinator manages a dry contact calibrated for disconnec on from the 230V power supply. The power
supply is separated with its own protec on (circuit breaker calibrated to suit the equipment controlled or its
transformer – max. 8 A).
Preferred connec on for NL LED spotlights.
Possible controls: ON/OFF with mer for all monochroma c spotlights, ON/OFF/Colour with NL RGBW LED
spotlights
230 V contact
All types of auxiliary
device
230 V
Transformer for ligh ng,
booster pump, etc.
maximum 8 A
Preferred connec on for Zodiac® NL LED spotlights (see
installa on manual)
: 230 VAC/12 VAC
(50/60 Hz) transformer
: Electrical protec on
: Auxiliary relay for
external controller or
switch
With 2 spotlights
With 1 spotlight