Zodiac Ei3 handleiding

20 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 14 van 20
Page 15
Page 14
Ei3 Saltwater Chlorinator | Installation Manual
7.2.2 White Light Operation
1. Press
.
2. Use to select “Aux/Light” then press .
3. Use to select “Aux 2/Light” then press .
4. Use toselect“On”,“O󰀨”,
or “Set Timers”, then press
.
5. Press to exit.
<
AUX 2
-OFF
-ON
-SET TIMERS
7.2.3 Color Light Operation
1. Press
.
2. Use to select “Aux/Light” then press .
3. Use to select “Aux 2/Light” then press .
4. Use toselectdesiredcolor,“O󰀨”,
“On”or“DeneColor”,thenpress
.
5. If“DeneColor”selected,use to select
desired color then press
.
6. Press to exit.
<
AUX 2 / LIGHT
-OFF
-ON
-DEFINE COLOR
<
COLOR LIGHT
-ALPINE WHITE
-SKY BLUE
-COBALT BLUE
-CARIBBEAN BLUE
-SPRING GREEN
-EMERALD GREEN
-EMERALD ROSE
-MAGENTA
-VIOLET
-SLOW SPLASH
-FAST SPLASH
-AMERICA
-FAT TUESDAY
-DISCO TECH
Note: Colour sequence is relevant for Zodiac colour
lights only. If other manufacturers lights are
installed the colour selection will vary
7.3 Programming/Timers
The controller has two internal operating timers.
The timers are used to define the length of time for
the filter pump to operate, and the length of time
for the Salt Water Chlorinator (SWC) to produce
chlorine. This offers the user the advantage of
running their variable speed pump longer at lower
flow rates, without having the chlorinator producing
the whole time.
In order to complete the timer program, it is
necessary to enter and validate both ON and
OFF times. If no timer is set, the filtration and / or
chlorination will run continuously
The filtration operating times must be sufficient to
correctly treat the water.
Example - single speed pump:
In Season filtration time: 8-10 hours per day.
Off Season filtration time: 4-5 hours per day.
Example - variable speed pump (when running at
lower speeds):
In Season filtration time: 12-14 hours per day
In Season SWC time: 8-10 hours per day
Off Season filtration time: 10-12 hours per day
Off Season SWC time: 4-5 hours per day
Once validated, The SWC will adopt the same
timers as the filtration pump. The chlorination time
must be equal or shorter than the filtration time.
The device will not accept a SWC timer longer than
or outside the programmed filtration time.
7.3.1 Reset Timers
1. Press
.
2. Use to select “Programming”
then press
.
3. Use to select “Reset Timers” then press .
The selected timers will be reset to 00:00.
7.3.2 Operation With an External Timer
In order for the controller to operate with an
external timer. All controller programs must be
cleared and the device must be on. After the
connection to the external timer is made, turn the
controller off then back on again.
7.3.3 Filter Pump Programming
1. Press
.
2. Use to select “Programming”
then press
.
3. Use to select “Filter Pump” then press .
4. Use to select “Pump Timer 1” or “Pump
Timer 2” then press
.
5. Use toselectthehourfortheltrationon
time then press
.
6. Use toselecttheminutesfortheltration
on time then press
.
7. Use toselectthehourfortheltrationo󰀨
time then press
.
8. Use toselecttheminutesfortheltration
o󰀨timethenpress
.
9. Press to exit.