Zodiac CAE Ducted handleiding

26 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 8 van 26
H0384600.A1.EN2012/10 7
2.6Electricalconnections
2.6.1Voltageandprotection
The electrical supply must be provided through a protection and circuit breaking device (not supplied)
complyingwiththestandardsandregulationsinforceinthecountrywhereitisinstalled,
Electricalprotection:30mAgroundfaultcircuitbreaker.
Acceptablevoltagevariationtolerance:±10%(duringoperation),
Electriccablesmustbefixed,
2.6.2Connections
Looseterminalsmaycausethesupplyterminalboardtooverheat,andwillvoidthewarranty.
Theappliancemustbeearthed.
Riskofelectricalshockinsidethedevice. Onlyaqualifiedandexperiencedtechnicianmustinstallthe
devicecables.Ifthepowercableisdamageditmustbereplacedbyaqualifiedtechnician.
2.6.3Cablesizes
Supply cable size: for cables of a maximum length of 20 metres (calculation basis: 5A/mm²), this must be
checkedandadapteddependingoninstallationconditions.

Option Voltage
Nominal
power
consumption
Maximum
power
consumption
Cablesize
Unit A A mm²
CAE508
Single
phase
withoutoptionorhotwaterbattery 230V50Hz‐ 17.5 37.1 3x6 3G6
Extraheating4.5kW 230V50Hz‐ 32.7 48.5 3x10 3G10
CAE508
three
phase
withoutoptionorhotwaterbattery 400V50Hz‐ 5.3 8 5x2.5 5G2.5
Extraheating9kW 400V50Hz‐ 18.5 22.5 5x6 5G6
CAE510
three
phase
withoutoptionorhotwaterbattery 400V50Hz‐ 8.5 14.5 5x4 5G4
Extraheating9kW 400V50Hz‐ 21.5 29 5x6 5G6
Extraheating18kW 400V50Hz‐ 34.5 43.5 5x10 5G10
CAE513
three
phase
withoutoptionorhotwaterbattery 400V50Hz‐ 11 17 5x4 5G4
Extraheating9kW 400V50Hz‐ 24 31.5 5x10 5G10
Extraheating18kW 400V50Hz‐ 37 46 5x10 5G10
Omega10
withoutoptionorhotwaterbattery 400V50Hz‐ 7.6 13 5x2.5 5G2.5
Extraheating9kW 400V50Hz‐ 20.6 27.5 5x6 5G6
Omega14
withoutoptionorhotwaterbattery 400V50Hz‐ 9 16 5x4 5G4
Extraheating9kW 400V50Hz‐ 22 30.5 5x6 5G6
Omega16
withoutoptionorhotwaterbattery 400V50Hz‐ 12 18.5 5x4 5G4
Extraheating18kW 400V50Hz‐ 38 47.5 5x10 5G10
Alimentation
Regulation
(HygroControl)
CAEsingle
phase
:230Vac‐50Hz
:contact(230Vac‐50Hz‐5Amaximum)
Circulatorconnectionor
controlofheatsource
Connectionofauxuiliary
pumporfilterclock
Hotwater
batter
y
o
p
tion
Mainsupply
230Vac50Hz‐
forremotefault
warninglight
Watercondenser
option

Bekijk gratis de handleiding van Zodiac CAE Ducted, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkZodiac
ModelCAE Ducted
CategorieNiet gecategoriseerd
TaalNederlands
Grootte6812 MB