Appendix
Rio3224-D3 Rio1608-D3 Reference Manual
37
SYNC messages
SYNC messages, and the [SYNC] indicator state (light, flash, off) inform you of the status of
the Dante network.
NOTE
The left [SYNC] indicator is green and the right one is orange.
The term “Flash x2” means that the indicator flashes twice cyclically, while the term “Flash x3”
means that the indicator flashes 3 times cyclically.
If the green [SYNC] indicator remains off, the device clock has not yet been determined. If the
green [SYNC] indicator is flashing, the device is the clock leader. If it is lit, the device is a clock
follower and the clocks are synchronized.
If the ID is blank in the table below, only the message will appear on the display.
ID Message Description
Explanation or
possible solution
Status indicators
NORMAL Functioning correctly as a
word clock follower.
This indicates that the
device is a word clock
follower.
DANTE WORDCLOCK
LEADER
Functioning correctly as
the word clock leader.
This indicates that the
device is the word clock
leader.
SYNCHRONIZING WITH
CONSOLE OR
CONTROLLER
Currently processing
synchronization within the
Dante network.
Wait until startup or
synchronization is
completed. It may take up
to 45 seconds for this to
be completed.
E01-003 WRONG WORDCLOCK! The word clock setting is
incorrect.
On the supported digital
mixer or in Dante
Controller, set the clock
leader and the sampling
frequency correctly.
E01-004 DANTE PORT DOES NOT
HAVE CONNECTION!
The Dante network is not
connected.
Check whether an
Ethernet cable might be
disconnected or broken.
Light Off
Flash Off
Off Light
Off Flash
Flash x2Off
E01-005 DANTE CONNECTION
ERROR!
Other Dante devices
cannot be found because
the Dante network
connections are incorrect.
Check whether the
Ethernet cable
connections are correct.
E01-006 DANTE IS NOT
WORKING BY GIGA BIT!
A device that does not
support Giga-bit Ethernet
is connected.
If you are transferring
audio via Dante, use
devices that support Giga-
bit Ethernet.
E01-007 DANTE IS WORKING AT
SECONDARY!
In the case of a redundant
network, communication
is occurring via the Dante
[SECONDARY] connector.
Check the circuit that is
connected to the Dante
[PRIMARY] connector.
E01-008 ERROR OCCURRED AT
SECONDARY PORT!
In the case of a redundant
network, a problem has
occurred in the circuit that
is connected to the Dante
[SECONDARY] connector.
Check the circuit that is
connected to the Dante
[SECONDARY] connector.
E01-010 DANTE IS NOT
WORKING BY GIGA BIT!
Functioning as the word
clock leader.
A device that does not
support Giga-bit Ethernet
is connected.
This indicates that the
device is the word clock
leader.
If you are transferring
audio via Dante, use
devices that support Giga-
bit Ethernet.
E01-011 DANTE IS WORKING AT
SECONDARY!
Functioning as the word
clock leader.
In the case of a redundant
network, communication
is occurring via the Dante
[SECONDARY] connector.
This indicates that the
device is the word clock
leader.
Check the circuit that is
connected to the Dante
[PRIMARY] connector.
E01-012 ERROR OCCURRED AT
SECONDARY PORT!
Functioning as the word
clock leader.
In the case of a redundant
network, a problem has
occurred in the circuit that
is connected to the Dante
[SECONDARY] connector.
This indicates that the
device is the word clock
leader.
Check the circuit that is
connected to the Dante
[SECONDARY] connector.
ID Message Description
Explanation or
possible solution
Status indicators
Flash x3Off
Light Light
Light Flash
Light Flash x2
Flash Light
Flash
Flash
Flash
Flash x2