10 MY8-SDI-ED Owner’s Manual
2 AE96/AE Switch
This switch is valid only when the Nat/Emu switch (
1) is set to ON. Typically,
leave this switch set to OFF. If you are using the card with a Yamaha DIO8, set
this switch to ON.
OFF: This card will be recognized as a Yamaha MY8-AE96 digital I/O card.
ON: This card will be recognized as a Yamaha MY8-AE digital I/O card.
Note:
MY8-AE96 mode (OFF setting) supports only double speed. You can select the 96 kHz
double channel on the host device, but it will not operate in double channel.
3 MUTE Switch
Typically, leave this switch set to OFF.
OFF: Audio will not be muted regardless of whether or not an HD/SD-SDI input
error is detected.
ON: Audio will be muted if an HD/SD-SDI input/output error is detected (the
SDI STATUS LED will light up in a color other than green.). Use this
setting if you want to use muted audio to indicate an error.
Note:
Keep in mind that connecting or disconnecting a cable may cause noise even if this switch
is set to ON.
4 TEST Switch
Be sure to leave this switch set to OFF. Otherwise, the card will not operate
properly.
Word clock settings
You cannot assign the MY8-SDI-ED as the master clock.
If you need to synchronize the host device to a house sync signal (external digital
system), use the WORD CLOCK IN connector to set the master clock of the host
device.
The audio I/O section of the MY8-SDI-ED features a sampling rate converter,
which will convert the sampling rate of the I/O signals depending on the settings
of the host device.