Handleiding
Je bekijkt pagina 3 van 27

1. GENERAL
INTRODUCTION
This manual is applicable only to models listed on the
cover page.
Procedures in this manual will apply to all
models unless specified. Pictures and illustrations can
be of any model unless they need to be model specific.
SPECIFICATIONS
Model Burners Total Input BTU / HR
WX24-4BN 4 143,000
WX24-4BP 4 143,000
WX36-6BN 6 198,000
WX-36-BP 6 198,000
WX60F-6B2
4GN
6 268,000
WX60F-6B2
4GB
6 268,000
WX60-10BN 10 340,000
WX60-10BP 10 340,000
Gas Pressures
• Manifold/Operating Pressure
Natural: 5 in. W.C.
Propane: 10 in. W. C.
Inlet Supply Pressure
•
Natural - Recommended 7 in. W. C.; Minimum 5
in. W. C.
• Propane - Recommended 11 in. W. C. ; Minimum
11 in. W. C.
• Maximum 14 in. W.C. (0.5 PSI) (Natural or
Propane)
INSTALLATION, OPERATION AND
CLEANING
For detailed installation, operation and cleaning
instructions, refer
to Instruction manual sent with each
unit. The manual is also available online at
www.vulcanequipment.com.
TOOLS
Standard
• Standard set of hand tools.
•
VOM with measuring micro amp current tester.
Any VOM with minimum of CAT III 600V, CE
certified. Sensitivity of at least 20,000 ohms per
volt can be used. In addition, meter leads must
also be a minimum of CAT III 600V.
• Clamp on type amp meter with minimum of
NFPA-70E CAT III 600V, UL/CSA/TUV listed.
• Temperature tester (K type thermocouple
preferred).
• Manometer.
Special
• Loctite® 246™ for use on door handle mounting
screws.
• 3/4" pipe tee and hose barb assembly for
temporarily checking manifold pressure when a
pressure tap is not available in the gas manifold
on some models.
• Pipe taps may be needed to clean or repair
internal threads on gas manifolds. Use a wire
brush to clean external pipe threads on fittings.
• Adaptor to test thermocouple closed circuit DC
voltages (purchase locally). Adaptors vary
between manufacturers. Example of one adaptor
type is in
Fig. 1.
Fig. 1
LUBRICATION
Anderson and Forrester (or comparable) valve grease
for top burner gas valves, top burner pilot valves, and
pressure tap plugs. Apply light coat to valve/plugs.
Apply light coat to valve/plug threads, Valve grease
must be insoluble in propane and natural gas.
WX RANGE - 1. GENERAL