4) Misalignment between the groove
in the inner shell of the heating
muffle and the groove of the
heating muffle
5) Low voltage
6) Wear of the inner shell of the
bracket
7) Wear of the inner shell of the
heating muffle
8) Worm shaft wear
4) Reinstall the inner shell of the
heating muffle
5) Check the voltage
6) Replace the inner shell
7) Replace the inner shell
8) Fix the worm shaft
6
The briquette does
not take shape
1) Wet raw material
2) Misalignment between the gutter
in the heating muffle and the
gutter in the inner shell
3) Excessive temperature
4) The inclination of the front worm
shaft is less than 20°
5) Electric thermocouple incorrectly
or incorrectly installed
6) Short circuit in the heater
7) Excess oil in the raw material
8) Loose belt
1) Dry the raw material
2) Reinstall the inner shell
3) Reduce the heating temperature
4) Sharpen the front rake
5) Install the electrical thermocouple
correctly
6) Check the circuit of the heating
coil
7) Repair the front rake of the worm
shaft
8) Tighten the belt
7
Steam comes out,
fire blows from the
tank
1) High raw material moisture
2) Heavy wear of the inner shell of
the bracket
3) Heavy wear of the inner shell of
the heating muffle
4)
The helical front scraper of the
worm shaft does not meet the
requirements
1) Dry raw material
2) Fix the inner shell
3) Fix the inner shell
4) Sharpen the worm shaft