Installation
3 Installation
3.1 Installation Instructions
Ÿ Only install the water heater in a heated area where
the temperature cannot be below freezing. The
warranty does not cover damage caused by
freezing.
2. All gas water heaters require proper and careful
installation to ensure safe and efficient operation.
This manual must be strictly observed.
6. The electrical connection requires disconnecting
the unit for maintenance and safety to turn off the
power to the water heater.
9. This water heater is for indoor installation only.
Ÿ The water heater must be securely mounted to a
wall or other suitable structure.
3. The manifold pressure is preset at the factory. It is
computer controlled and does not require
adjustment.
4. Maintain proper maintenance space when installing
equipment. So that it can be easily connected or
removed.
5. The water heater must be installed in a place where
it can be used at any time with a suitable amount of
flammable air. The indoor water heater can be
directly ventilated.
7. Do not install the unit where the exhaust vents point
to any openings in the building or where noise may
disturb the neighbors. Ensure that the vent terminal
meets the required distance from any door or
opening by local regulations to prevent exhaust
gases from entering the building.
Ÿ The water heater cannot be installed on the floor.
1. Follow all local regulations, or in the absence of local
regulations, follow the current version of the US
National Gas Code: US ANSI Z 223. 1/NFPA 54 or
Canada b 149. 1 natural gas, propane installation
specifications.
8. Carefully select the installation location of the
water heater, lint and fine powder Contaminants
such as flour can block the air intake and reduce fan
operation. This in turn, can lead to burning
anomalies and shorten the life of the water heater.
Regularly ensure that the area around the water
heater the air inlet are free of dust, debris and other
contaminants.
WARNING
Water temperatures above 125 °F (52 °C)
can cause severe burns or burns. The
factory water temperature is set at 107 °F
(42 °C) to minimize the risk of burns. Always
check the water temperature before taking
a shower or shower.
Do not disconnect the power supply if the
ambient temperature is below freezing. The
frost protection system is only effective
when the device has power. If the heat
exchanger is damaged due to freezing, it is
not covered by the warranty.
Do not use this product if it is immersed in
water. Call a qualified installer or service
facility immediately to replace the water-
immersed water heater. Do not attempt to
repair the unit. Must be replaced.
Failure to follow these warnings can result
in serious personal injury or death.
Do not store or use gasoline or other
flammable materials, vapors or liquids near
this equipment.
Do not connect to water or gas connections
as this can damage the valve and can cause
serious injury or death.