Please also read the full instructions that follow this section.
Installation summary
For bonded constructions in dry
areas a high temperature acrylic
adhesive can be used to bond the
Ultra-12panelstothesuboor.
Presstheboardsdownrmly
into the adhesive to create the
necessary adhesion.
Starting from the manifold
locationttheservicepanels
following the pipe layout shown
on the working drawings.
For bends use the curve service
panels, snapping or cutting the
straight service panels at 45° and
butting them tightly together.
Ensurethesuboorisclean,dry
and prepared to an SR1 standard.
Seesuboorconsiderationspage
for more information.
For bonded constructions in wet
or dry areas and compatible
S1orS2exibletileadhesiveis
recommended.
Presstheboardsdownrmly
into the adhesive to create the
necessary adhesion.
Fit the curve panels at the end of the room referring to the working
drawings.
Inlltheheatedareawiththestraightpanels.
Theplainpanelscanthenbeusedinareaswhereunderoorheatingwill
not be installed, i.e. under kitchen units.
1 2
3 4
5
SR1
2 m < 3 mm