Warmup VLo Ultra-12 handleiding
Handleiding
Je bekijkt pagina 24 van 32

24
Troubleshooting
ISSUE 1 - Excessive movement or creaking
PROBLEM SOLUTION
Suboornotstructurallysoundorlevel
causingtheUltra-12boardstoexand
rub
Retthepanelsinaccordance
with this manual.
ISSUE 2 - Cracked tiles
PROBLEM SOLUTION
TimberSuboor-Thereisexcessive
movementinthesuboorcausingthe
oortoexleadingtocrackedtiles
Theissuewiththesuboorhas
to be resolved otherwise the
tiles will continue to crack
Thesuboorwasnotsucientlylevel
prior to the system being installed
and there are air gaps between the
Ultra-12panelsandthesuboor.
Theissuewiththesuboorhas
to be resolved otherwise the
tiles will continue to crack
ISSUE 3 - Ultra-12 boards are unstable during installation
PROBLEM SOLUTION
Suboornotlevel
Ensurethesuboorissmooth,
atandleveltoSR1standards
as required
Excessive tension in the pipe
Glue the Ultra-12 boards to the
suboor
ISSUE 4 - Excessive / Insucient heat output
PROBLEM SOLUTION
Incorrect water temperature
Refer to System Performance
chart to calculate the required
water temperature
Bekijk gratis de handleiding van Warmup VLo Ultra-12, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Warmup |
| Model | VLo Ultra-12 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 8703 MB |