Ensure that the sensor is tested
before the plywood layer has
beentted.Warmupthermostats
typicallyusea10kΩsensor.
Please to refer to the thermostat
manual for further details.
The expected resistance
depending on temperature is
listed below.
Sensor resistance test
Sensor resistance by temperature - NTC10K
Temperature Resistance Temperature Resistance
0 °C 32.5kΩ 16 °C 15.0kΩ
2 °C 29.4kΩ 18 °C 13.7kΩ
4 °C 26.6kΩ 20 °C 12.5kΩ
6 °C 24.1kΩ 22 °C 11.4kΩ
8 °C 21.9kΩ 24 °C 10.5kΩ
10 °C 19.9kΩ 26 °C 9.6kΩ
12 °C 18.1kΩ 28 °C 8.8kΩ
14 °C 16.5kΩ 30 °C 8.1kΩ
Testing information