Warmup VLo Ultra-12 handleiding
Handleiding
Je bekijkt pagina 19 van 32

19
Step 5A - Laying a tile oor covering
1
2
•CovertheUltra-12systemwithafullbedofcompatibleS2exibletile
adhesive using a notched trowel ensuring there are no air gaps.
• Afterlayingthersttileremoveandensurethetileisgettingafull
coverage of adhesive from your application. Ensure the width of the grout
line is in line with the manufacturers instructions for the size and type of
tile being used.
• Grouttheoorassoonaspossibleasperthetileadhesive
manufacturer’s instructions.
Tiles must not be removed once the adhesive has set, doing so
could damage the pipes.
DO NOT switch the system on until the tile adhesive and grout has
fully cured. DO NOT use the heater to accelerate the curing process
of the adhesive or levelling compound.
The smallest tile size allowable over Ultra-12 is 200 mm x 200 mm,
alevellingcompoundmustrstbeappliedwhenusingsmaller
tiles, see 5B. Any tile adhesive used must be compatible for
compressible panels such as Ultra-12.