Before installing the pipework in
the panels it is advised to sweep
or vacuum the oor area to clear
any debris.
Install the pipe in line with the
projects working drawings.
Econna-12 panels are structural,
therefore additional pipe
channels must not be routed.
Installation summary
Measure and cut the pipe so
that it reaches both the ow and
return ports on the manifold.
Refer to the manifold manual
for detailed information on
mounting, pressure testing and
commissioning.
Use Warmup pipe bend supports
where the pipe exits the oor at
the manifold location.
Lay a minimum 6 mm ooring
grade plywood in the opposite
direction to the Econna-12 panels.
This layer must be screwed to the
Econna-12 panels to complete the
structural deck.
The plywood should be positioned
so that each plywood panel
overlaps the tongue and groove
edges of the Econna-12 panel by
300 mm.
Lay your chosen oor covering
in accordance with oor
manufacturers instructions.
Before installing the nal
Econna-12 panel, drill another
12.5 mm hole in this last panel at
a 20° angle where the return pipe
needs to drop into the joist space.
Feed the pipe through the hole
through to the manifold location,
notching/drilling the joists as
required in line with building
regulations.
7
8
9 10
11
Install your Warmup
thermostat referring to their
installation instructions. The
system must be connected to and
controlled with a thermostat and
sensor.