14
Step 5 - Lay the service pipe
Plan the circuit layout ensuring
that the ow and return pipes
can connect from the manifold
to their respective heated area
without crossing each other.
1 2
If the project has been supplied with a set of working drawings, follow
the provided pipe layout. Ensure each circuits details are recorded in the
commissioning log provided in the Warmup manifolds installation manual.
First install the service pipe in the
joist location, ensuring there is
excess ow and return pipe at the
manifold location which can be
cut later after the pipe has been
laid.
Use Warmup pipe bend supports
and Warmup clips where the pipe
exits the oor at the manifold
location.
Secure the pipe to the insulation layer using Warmup clips after the bend
supports and then every 500mm.
Secure bends in the pipe at the beginning, middle and end of the turn.
3