Troubleshooting
ISSUE 1 - Pipes releasing from castellations
PROBLEM SOLUTION
Castellations are damaged
Place in alternative castellations
Use 60mm pipe staples to
secure the pipe in place
Suboor not level resulting in the
panels deecting downwards under
trac
Ensure the suboor is to a SR2
standard
ISSUE 2 - Panels lifting from corners
PROBLEM SOLUTION
Tension from pipes is causing the
panels to lift
Use 60mm pipe staples to
secure the panels in place
ISSUE 3 - Running out of pipe/excess pipe leftover
PROBLEM SOLUTION
When laying the pipe, incorrect pipe
spacing has been used.
The pipe will have to be
installed again at the correct
spacing as per your design
layout.
ISSUE 4 - Floor overheating at ow and returns to manifold
PROBLEM SOLUTION
As the pipes reach the manifold they
are tightly packed together which will
give a higher heat output.
The pipes will need to be
insulated using conduit or pipe
lagging.
ISSUE 5 - Excessive/insucient heat output
PROBLEM SOLUTION
Incorrect water temperature
Refer to System Performance
chart to calculate the required
water temperature