Step 1 - Suboor considerations
The concrete suboor must be clean, level, solid, structurally sound and
dimensionally stable. Ensure the suboor is prepared to an SR2 standard
(SR2 - the maximum permissible departure over a 2 m straight is 5 mm).
If necessary an appropriate blinding layer should be applied.
Any materials on or within the suboor must be suitable for
supporting underoor heating systems. If using temperature
sensitive materials beneath the heating cable, such as damp
proong or tanking systems, contact the manufacturer for advice.
Where tiles are to be used, ensure that the suboor meets the
local tiling standard requirements.
Do not commence installation without ensuring that the resulting
oor construction will meet the requirements of the oors
intended use and its nish.