14
Settings
Advanced settings Sensors &
Application
Internal Air Sensor Oset
+/- 10°
Probe 1 Connected On/O
Type
5, 10, 12, 15, 33, 100K
Oset
+/- 10°
The 7iE uses a 10K sensor. However, if using a
7iE to replace an existing thermostat you must
change to the correct sensor type.
Probe 2 Connected On/O
Type
5, 10, 12, 15, 33, 100K
Oset
+/- 10°
If a 2nd sensor is wired into terminals 6 & 7
it must be switched on here to act as a limit
sensor.
Floor
thermostat
(Probe 1 On, Probe
2 O. See Appendix
1.0 for alternative
thermostat use
cases)
Control
Floor
Remote Air
Regulator
Limit
None/Air
Choose to switch the method of control for the
sensor; oor sensor, remote air sensor if not
installed underneath the oor or regulator
mode.
Regulator Mode; Heating is on for X% out of
control cycle (default 10mins). Heating is o for
remaining time.
Swap Probe Usage On/O
Floor type
*
Tile/Stone
Laminate
Carpet
Wood
Vinyl
Other
Choose the oor type of your installation. This
will apply dierent temperature and overheat
limits to the 7iE.
*
Not applicable if conventional heating system was selected.
Display, cont’d Night period Set the Start and
End period
This is the time when you usually go to bed at night and wake
up in the morning. The brightness of “Night” mode will begin
and end using this time.
Screen lock On/O
Locks the 7iE screen to prevent any unauthorised changes to
the 7iE. Requires a 4 digit code to access the menu or make
changes.
Advanced Settings