OPERATING MANUAL
VERSION 02/2018 ORDER NUMBER DOC 2366717
7 OPERATION
7.1 TRAINING THE OPERATING STAFF
The operating sta must be qualied to operate the entire system.
The operating sta must be familiar with the potential risks associated with improper
behavior as well as the necessary protective devices and measures.
Before work commences, the operating sta must receive appropriate system training.
7.2 ELECTRICAL DISCHARGE
In the nozzle area of the spray gun electrical discharges can occur. They are completely
non-hazardous for human health. However, they can cause a shock reaction.
CAUTION
Electrical discharge!
Shock reaction.
Maintain a safety distance of 100 mm; 4 inches from the nozzle area of the spray gun
during the spraying process and at least 20 seconds after the end of the spraying
process.
Danger zone
A
A
A
A
A = 100 mm
A = 4 inch
B_03368
In order to avoid electrical discharges, a distance of 100mm or
4inches must be maintained from the work piece and other
grounded objects during and after the spraying process for
at least 20 seconds.