Wachendorff WDGA 58S handleiding
Handleiding
Je bekijkt pagina 22 van 34

Technical Manual
WDGA with IO-Link
4 - IO-Link
© Wachendorff Automation GmbH & Co. KG
16
4.3.3 Standard parameter events
Event
Id
Event
Type
Description
0x4000
IOLD_EVENT_TEMP
ERATURE_FAULT_
OVERLOAD
Error
Actual operating temperature is above
maximum value or below minimum
value
0x4210
IOLD_EVENT_DEVI
CE_TEMPERATURE
_OVERRUN
Warning
This warning is generated if the actual
operating temperature is above the
maximum operating temperature
specification decremented by 10°C.
0x4220
IOLD_EVENT_DEVI
CE_TEMPERATURE
_UNDERRUN
Warning
This warning is generated if the actual
operating temperature is below the
minimum operating temperature
specification incremented by 10°C.
0x5000
IOLD_EVENT_DEVI
CE_HARDWARE_FA
ULT
Error/Al
arm, not
recover
able
Hardware error occured, device must
be exchanged
0x6000
IOLD_EVENT_DEVI
CE_SOFTWARE_FA
ULT
Error/Al
arm, not
recover
able
Software error occured, device must
be exchanged
0x8D18
IOLD_EVENT_SIGN
AL_COUNTER_MUL
TICHANNEL_REACH
_LIMIT
Notificat
ion
One of the Switching counter channels
reached its limit – check status
0x8D19
IOLD_EVENT_SIGN
AL_COUNTER_MUL
TICHANNEL_OVERF
LOW
Warning
One counter stopped because it
overflowed the maximum value -
check status of switching counters
0x8CFF
IOLD_EVENT_LOW_
SIGNAL_QUALITY
Error,
recover
able
Magnetic field is too weak or too
strong, check environment
0x8D10
IOLD_EVENT_CUST
OMER_TEMPERATU
RE_MAX_TRESHOL
D_OVERRUN
Warning
This warning is generated if the actual
operating temperature is above the
maximum operating temperature
defined by the customer.
0x8D20
IOLD_EVENT_CUST
OMER_TEMPERATU
RE_MIN_TRESHOL
D_UNDERRUN
Warning
This warning is generated if the actual
operating temperature is below the
minimum operating temperature
defined by the customer.
0x1848
IOLD_EVENT_SING
LETURN_MAGNETI
C_FIELD_TOO_STR
ONG
Error
Magnetic field of sensor is too strong,
maybe environmental magnetic field
impacts the measurement
0x1849
IOLD_EVENT_SING
LETURN_MAGNETI
C_FIELD_TOO_WEA
K
Error
Magnetic field of sensor is too weak,
maybe magnet is broken
Bekijk gratis de handleiding van Wachendorff WDGA 58S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.