Vulcan C24DA10 handleiding
Handleiding
Je bekijkt pagina 38 van 65

Disconnect the electrical power to the machine and follow lockout / tagout procedures.
Shut off the steam before servicing the unit and follow lockout / tagout procedures.
All gas joints disturbed during servicing must be checked for leaks. Check with a soap and water solution
(bubbles). Do not use an open flame.
ADJUSTABLE PILOT BURNER (1)
SOLARONICS BURNER ASSEMBLY (1) NON-
ADJUSTABLE PILOT
A. CHECK ALL JOINTS PRIOR TO THE GAS VALVE (SOLENOID) BEFORE LIGHTING THE UNIT.
B. CHECK ALL JOINTS BEYOND GAS VALVE (SOLENOID) AFTER UNIT IS LIT.
1. Remove FRONT, RIGHT AND LEFT SIDE
PANELS
2. Turn the gas combination control valve off.
C24GA AND C24DA SERIES CONVECTION STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS
F35425 Rev. E (0119) Page 38 of 65
Bekijk gratis de handleiding van Vulcan C24DA10, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Vulcan |
Model | C24DA10 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 16865 MB |